The Illuminance Spectrophotometer CL-700A enables high-speed, high-accuracy measurement of optical properties of light sources, including illuminance, chromaticity, wavelength characteristics, color rendering index (CRI), and more. Covering a wide wavelength range from visible light through the near-infrared light up to 1,000 nm, it is suitable for evaluating LEDs and OLEDs, as well as optical systems used in projectors, image sensors, smartphone cameras, AR/VR devices, and horticulture applications.

Spektrofotometer Iluminasi CL-700A

The Illuminance Spectrophotometer CL-700A combines Konica Minolta’s expertise in optical measurement with high performance to provide a reliable solution for evaluating light with accuracy and speed. Designed for users who require both spectral accuracy and practical operation, the CL-700A measures a wide range of optical properties, including illuminance, chromaticity, correlated color temperature (CCT), and spectral power distribution, as well as color quality metrics such as Color Rendering Index (CRI). This comprehensive capability supports applications ranging from basic brightness and color checks to detailed spectral analysis for quality control and research & development.

The CL-700A supports a wide illuminance measurement range from 0.01 lx to 200,000 lx, making it adaptable to many measurement applications. It delivers stable illuminance measurements from very low light levels to high-brightness conditions, enabling consistent evaluation of lighting performance in both dim and high-output settings. The spectral measurement range of this light measurement instrument extends from visible light into the near-infrared region, up to 1,000 nm, supporting modern lighting technologies and applications that go beyond the visible spectrum, including NIR LEDs and optical systems used in sensing workflows.

Measurement accuracy and speed are key design priorities of the CL-700A. Even under low illuminance conditions, the instrument delivers stable, repeatable results in a short measurement time—measuring down to 0.01 lx in approximately 5 seconds, with a Super FAST mode that enables measurements in as little as 0.3 seconds. This high-speed performance improves efficiency in laboratory testing and production environments, helping shorten evaluation cycles, reduce waiting time, and support higher throughput for quality assurance and development.

For applications that require evaluation of light distribution over a wider area, the CL-700A supports multi-point measurement configurations. Multiple units can be operated simultaneously to capture synchronized measurement data at different locations, allowing users to efficiently assess illuminance uniformity and spatial light distribution without repositioning the instrument multiple times.

Despite its advanced performance, the CL-700A features a compact and versatile design. It can be used as a handheld instrument or easily integrated into fixed measurement stations and automated production lines. Flexible connectivity options and the dedicated CL-S30 measurement software enhance usability by enabling intuitive operation, real-time data visualization, and efficient data management, supporting smooth integration into existing measurement workflows.

 

 

Spektrofotometer Iluminasi CL-700A

  • Wide illuminance measurement range: 0.01 lx up to 200,000 lx
  • Wide wavelength range: Visible to Near-Infrared (NIR) [360 – 1,000 nm]
  • High-speed measurement, especially in low illuminance; approximately up to 5 seconds in NORMAL mode and 0.3 seconds in Super FAST mode
  • Multipoint measurement up to 15 units
  • Compact, lightweight design for handheld use and easy integration into inspection/manufacturing equipment
  • Automatic zero calibration/wavelength compensation function
  • Includes CL-S30 software for device control, real-time data visualization, and easy data output and storage

 

Spektrofotometer Iluminasi CL-700A

Illuminance meter classComplies with JIS C 1609-1:2006 Special type illuminance measuring instruments *1

Complies with DIN 5032-7:1985 classB *2

Wavelength range360 to 1000 nm
Output wavelength pitch1 nm
Spectral bandwidthApprox. 10 nm (half bandwidth)
Wavelength precision *3±0.3 nm (Centroid wavelengths of 435.8 nm, 546.1 nm, 696.5 nm, and 912.3 nm as specified in JIS Z 8724:2015)
Measuring range0.01 to 200,000 lx (chromaticity accuracy guaranteed range is 0.5lx or more)
Accuracy *4 (Standard Illuminant A)Ev (Illuminance): ±2%±1 digit of displayed value

xy: ±0.0015 (5 to 200,000 lx)

xy: ±0.003 (0.5 to 5 lx)

Repeatability (2σ) *4 (Standard Illuminant A)xy: 0.0005 (50 to 200,000 lx)

xy: 0.001 (10 to 50 lx)

xy: 0.002 (5 to 10 lx)

xy: 0.004 (0.5 to 5 lx)

V(λ) mismatch (f1‘)Within 1.5% of spectral luminous efficiency V (λ)
Directional response (f2)Ev: Within 3%
Temperature dependence (fT)Ev: ±3%

xy: ±0.003

Humidity resistance (fH)Ev: ±3%

xy: ±0.003

Measurement time *5Super FAST mode: Within 0.3 seconds

FAST mode: Within 0.5 seconds

NORMAL mode: Approximately 0.5 to 5 seconds

Measurement functionX,Y,Z

Ev,x,y

u’,v’

Tcp (Correlated color temperature), duv

λd (Dominant wavelength), Pe (Excitation purity)

Ra (General color-rendering index)

Ri (i=1~15) (Special color-rendering indexes)

TM-30-20 (when using CL-S30) *6

TLCI (when using CL-S30) *6

SDCM (when using CL-S30) *6

Ev’,S/P

EML (Equivalent Melanopic Lux)

PPFD

Ee (Irradiance) (when using CL-S30) *6

Ee(λ) (Spectral irradiance)

Spectral graph, Peak wavelength *6

Other functionsAutomatic zero calibration/wavelength correction

User calibration data input/output *6

Averaged measurement

Continuous measurement (when using CL-S30) *6

Multi-point measurement (up to 15 units) *6

Color matching functions: CIE 1931(2° Standard Observer), CIE1964(10° Standard Observer), CIE170-2(2°), CIE170-2(10°)

Display languagesEnglish, Japanese, Simplified Chinese
InterfaceUSB 2.0, Ethernet
PowerUSB bus power (when using USB), PoE (when using Ethernet, compliant with IEEE 802.3af)
Operation temperature / humidity range0 to 40°C, relative humidity of 85% or less (at 35°C) with no condensation
Storage temperature / humidity range-10 to 45°C, relative humidity of 85% or less (at 35°C) with no condensation
Size (W × H × D)80 × 170.5 × 35 mm
WeightApprox. 214 g

*1: This instrument does not comply with the following requirements for JIS C1609-1:2006 General type AA class illuminance meters:
• When Speed Mode is set to NORMAL mode, Range 7-10 do not comply with “5.5 Display characteristics (response time)”
• Temperatures below 0°C are outside the operation temperature range, non-compliant with “5.7 Temperature characteristics”
• No display, non-compliant with “6.3 Display”
All other requirements are compliant.
*2: Within an illuminance range of 1 lx or higher
*3: Based on Konica Minolta test standards (temperature change ≤2°C after zero calibration).
*4: NORMAL mode (at 23°C ±2°C, relative humidity ≤75%).
*5: The measurement time is the value under the following conditions:
•Time from measurement request from the operating terminal to completion of result reception from the measuring instrument
•When connected via USB
•Super FAST mode when Manual range setting is active
•When Buzzer Drive Mode is OFF
(Note: When 15 points are connected (via Ethernet), the measurement time is within measurement time shown + 1 second)
*6: CL-S30 can be used when connected. There are no communication commands to execute these functions
**Specifications subject to change without notice.

 

 

Spektrofotometer Iluminasi CL-700A

Unduhan Katalog: Unduh PDF (8.57 MB)

Panduan Pemilik: Unduh PDF (1.20 MB)

Software for Light Measurement CL-S30: Download

Spektrofotometer Iluminasi CL-700A



    Semua bidang yang ditandai dengan (*) wajib diisi.


    *Kirim*Data Anda akan diproses sesuai dengan ketentuan kami Kebijakan pribadi.
    *Email kami langsung dengan masalah pengiriman formulir apa pun