Spectrophotometer CM-17d / CM-16d
The Konica Minolta Spectrophotometer CM-17d and Spectrophotometer CM-16d, successors of the widely popular CM-700d and CM-600d models, respectively, bring enhanced accuracy and reliability to digital color measurement and management. With new and improved features, these spectrophotometers are suited for a range of industries, including plastics, consumer electronics, paints and coatings, automotive interior, personal care, and more, offering superior performance in color analysis and quality control.
These spectrophotometers offer high inter-instrument agreement (IIA) and repeatability, ensuring that colors are accurately and consistently communicated and reproduced from suppliers to manufacturers of the final product. In particular, the Spectrophotometer CM-17d features an inter-instrument agreement (IIA) and repeatability of ΔE*ab < 0.12 and ΔE*ab < 0.02, respectively, offering reliable and consistent color measurement across the global supply chain. Moreover, while maintaining compatibility with previous models, these spectrophotometers offer improved accuracy in measuring black color and boast a faster measurement speed, enhancing productivity and efficiency.
The Spectrophotometer CM-17d and Spectrophotometer CM-16d maintain the vertical alignment design for ergonomic comfort and easy sample placement. These portable color measurement instruments come with various measuring apertures, suitable for measuring samples of different sizes, including samples with shaped or curved surfaces. One standout feature, the camera viewfinder, available with the Spectrophotometer CM-17d, provides a live preview of the measurement target for easy positioning. Both spectrophotometers also offer the option of a wireless LAN/Bluetooth module for effortless data transfer and connectivity.
Augment your setup with a convenient screw/tripod hole at the front of both spectrophotometers, enabling straightforward installation of custom adapters/jigs or robotic arms. These spectrophotometers integrate seamlessly into automated systems, boosting productivity and efficiency in manufacturing and quality control operations. Notably, the Spectrophotometer CM-17d is equipped with a new cradle* that facilitates zero calibration and charging. It also features a dedicated compartment for storing the white calibration cap. An optional custom adapter/jig is also available to support measurements in an upside-down orientation, making these spectrophotometers even more versatile.
The Spectrophotometer CM-17d and Spectrophotometer CM-16d are backed by various software to enhance functionality. The Configuration Tool CM-CT1 software simplifies setups and ensures measurement standardization across sites. Further enhancing functionality is the optional SpectraMagic NX2 software, equipped with custom illuminants and color formulas, data tagging, QC template sharing, and more. These spectrophotometers also boast the Wavelength Analysis & Adjustment (WAA) function that checks and corrects any wavelength shift during each calibration, ensuring optimum measurement conditions.
*Optional for Spectrophotometer CM-16d
Spectrophotometer CM-17d / CM-16d
- High Inter-Instrument Agreement (IIA):
- CM-17d: ∆E*ab< 0.12; Average of 12 BCRA Series II color tiles
- CM-16d: ∆E*ab< 0.20; Average of 12 BCRA Series II color tiles
- High repeatability with improved measurement accuracy of black color:
- CM-17d: within ∆E*ab 0.02
- CM-16d: within ∆E*ab 0.04
- Fast measurement Speed of approx. 0.7s (SCI or SCE)
- User-defined illuminants*1 and color indexes
- Live preview of measurement target with camera viewfinder function*2
- Various measuring aperture, with or without optical glass, for different applications.
- CM-17d: Ø8 mm/Ø11 mm (MAV); Ø3 mm/Ø6 mm (SAV)
- CM-16d: Ø8 mm/Ø11 mm (MAV)
- Wavelength Analysis & Adjustment (WAA)* for routine checks of spectrophotometer performance.
- Optional wireless LAN/Bluetooth module
*1 Optional Color Management Software SpectraMagic NX2 Pro (Ver.1.3 or later) is required.
*2 The camera viewfinder function is only available on CM-17d.
Spectrophotometer CM-17d / CM-16d
Model | CM-17d | CM-16d |
Illumination/viewing system | di:8°,de:8° (diffuse illumination: 8° viewing), SCI (specular component included) / SCE (specular component excluded) switchable |
Applicable standards for illumination/viewing system | Conforms to ISO7724/1, CIE No.15 (2004), ASTM E 1164 (SCI), DIN5033 Teil7, JIS Z 8722 Condition c standard |
Integrating sphere | Ø40 mm |
Detector | Dual 32-element silicon photodiode arrays |
Spectral separation device | Planar diffraction grating |
Wavelength range | 400 nm to 700 nm |
Measurement wavelength pitch | 10 nm |
Half bandwidth | Approx. 10 nm |
Reflectance range | 0 to 175%; Resolution: 0.01% |
Light source | Pulsed xenon lamp (with UV cut filter) |
Measurement time | Approx. 0.7 s (Measurement mode: SCI or SCE, from pressing trigger button to measurement completion) |
Minimum measurement interval | Approx. 1.5 s (Measurement mode: SCI or SCE) |
Battery performance | Approx. 2,000 measurements (approx. 1,000 measurements when using Optional WLAN/Bluetooth module) when measurements are taken at 10-second intervals at 23°C with the dedicated lithium battery, without using electric view finder |
Measurement area/ Illumination area | MAV: Ø8 mm/Ø11 mm SAV: Ø3 mm/Ø6 mm *Can be changed by replacing the target mask and switching the lens position | MAV: Ø8 mm/Ø11 mm |
Repeatability | Standard deviation within ΔE*ab 0.02 (When a white calibration plate is measured 30 times at 5-second intervals after white calibration under Konica Minolta standard conditions) | Standard deviation within ΔE*ab 0.04 (When a white calibration plate is measured 30 times at 5-second intervals after white calibration under Konica Minolta standard conditions) |
Inter-instrument agreement | Within ΔE*ab 0.12 (Based on average for 12 BCRA Series II color tiles; MAV SCI; compared to values measured with a master body under Konica Minolta standard conditions) | Within ΔE*ab 0.2 (Based on average for 12 BCRA Series II color tiles; MAV SCI; compared to values measured with a master body under Konica Minolta standard conditions) |
Display | 2.7-inch TFT color LCD with reversible portrait viewing mode |
Internal Performance Check | WAA (Wavelength Analysis & Adjustment) Technology*1 |
Interface | USB 2.0; WLAN (IEEE 802.11 b/g/n)/Bluetooth(Ver.4.1, SPP-compatible.) Optional WLAN/Bluetooth module required*2 *3 |
Camera viewfinder function | Using internal camera; Images can be shown on display | – |
Observer | 2° Standard Observer, 10° Standard Observer |
Illuminant | A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4, LED-B5, LED-BH1, LED-RGB1, LED-V1, LED-V2, User-defined illuminant*4 (Max. 3 types) (Simultaneous evaluation with two light sources possible) |
Display items | Colorimetric values/graph, color difference values/graph, spectral graph, pass/fail judgment, pseudocolor |
Color spaces | L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, and color difference in these spaces; Munsell (C) |
Indices | MI, WI (ASTM E313-73/ASTM E313-98); YI (ASTM E313-73, ASTM D1925); ISO brightness (ISO2470); WI/Tint (CIE); Tristimulus Strength; Opacity; Grey scale (ISO 105-A05); gloss value; User index*5, Blackness (My) (ISO18314-3/DIN55979); Jetness (Mc) (ISO18314-3); Undertone (dM) (ISO18314-3) |
Color difference equations | ΔE*ab (CIE1976); ΔE*94 (CIE1994); ΔE00 (CIEDE2000); CMC (l:c); Hunter ΔE; DIN99o; FMC-2; ΔE*94 (Special)*6 |
Data memory | 1,000 target data + 5,000 sample data |
Power | AC power supply: USB Type-C AC adapter (Power Delivery compatible, 15 W or more) Battery: Lithium-ion battery (removable) USB charging: USB bus power (with lithium-ion battery installed) |
Charging time | Approx. 3.5 h (rapid charge) / Approx. 6 h(standard) |
Size | Approx. 79(W)×230(H)×128(D) mm |
Weight | Approx.700 g (Lithium-ion battery included) | Approx.660 g (Lithium-ion battery included) |
Operating temperature/ humidity range | Temperature: 5 to 40°C; Relative humidity: 80% or less (at 35°C) with no condensation |
Storage temperature/ humidity range | Temperature: 0 to 45°C; Relative humidity: 80% or less (at 35°C) with no condensation |
*1 The WAA function is available free of charge for the first year after purchase and can be continued in the second year and beyond by having the instrument serviced and calibrated.
*2 Requires optional accessory WLAN/Bluetooth module (CM-A300).
*3 WLAN security supports WPA2-PSK (WPA2-Personal) and WPA-PSK (WPA-Personal) for the ad hoc method, and WPA3-PSK (WPA3-Personal), WPA2-PSK (WPA2-Personal) and WPA-PSK (WPA-Personal) for the infrastructure method.
*4 Optional Color Data Software SpectraMagic NX2 Pro (Ver.1.3 or later) is required for setting user-defined illuminants and user indexes.
*5 Configuration Tool CM-CT1 (Ver. 1.5 or later) and a valid Color Data Software SpectraMagic NX2 license are required for setting user indices.
*6 When comparing two colors, use ΔE*94(Special) if one is not specified as standard.
**Specifications subject to change without notice.
Spectrophotometer CM-17d / CM-16d
Catalog Download: Download PDF (2.15 MB)
Owner’s Manual: Download PDF (7.40 MB)
Configuration Tool CM-CT1 software: Download