The Skin Analysis Software CM-SA2, designed to work seamlessly with Konica Minolta’s spectrophotometers, provides an efficient way to measure a variety of skin-related indices such as Melanin Index, Hemoglobin Index (Hb), Hemoglobin Oxygen Saturation Index (Hb SO2), and Individual Typology Angle (ITA°). This user-friendly software is ideal for professionals and researchers in the health and beauty industry, including dermatology, cosmetics, etc., offering precise and reliable data to analyze skin conditions or assess product performance with ease.

CM-SA2 Skin Analysis Software

The Konica Minolta CM-SA2 skin analysis software delivers precise, easy-to-use tools for measuring various skin health indices. Building on the success of its predecessor, the CM-SA, this upgraded model introduces advanced features that offer significant advantages across industries and sectors like cosmetics, skincare, dermatology, nutraceuticals, and pharmaceuticals.

With the CM-SA2, users can simultaneously measure key skin parameters such as Skin Color, Melanin Index, Hemoglobin Index (Hb), Hemoglobin Oxygen Saturation Index (Hb SO2), and Individual Typology Angle (ITA°). Its seamless integration with the Spectrophotometer CM-17d’s camera viewfinder ensures accurate positioning and easy alignment of the measurement target. Each captured image is automatically saved and linked to the respective data, allowing users to verify measurement positions later through the stored visuals.

The software also streamlines data management with its flexible, user-friendly interface. Users can easily customize measurement parameters and conditions to suit their specific needs, adding or removing fields as required. Additionally, all measurement data can be effortlessly exported for further analysis or processing in Excel® or similar spreadsheet applications.

 

 

CM-SA2 Skin Analysis Software

  • Skin-Related Indices Measurement
    • Melanin Index
    • Hemoglobin Index (Hb)
    • Hemoglobin Oxygen Saturation Index (Hb SO2)
    • Individual Typology Angle (ITA°)
  • Colorimetric Measurement
    • L*, a*, b*, C*, h
    • Munsell value (Hue, Value, Chroma)*1
  • Multiple language supported: Japanese, English, Chinese (Simplified and Traditional), Korean
  • Camera viewfinder function*2
  • Output of measurement data in CSV text format
  • Able to read CM-SA data.

*1 Munsell value care calculated for 2° observer and Standard Illuminant C.
*2 only applicable with Konica Minolta Spectrophotometer CM-17d

 

 

CM-SA2 Skin Analysis Software

Skin data displayMelanin Index

Hb Index [Total hemoglobin (oxidized + reduced) index]

Hb SO2 Index (%) [Hemoglobin oxygen saturation index (%)]

ITA° [Individual Typology Angle]

ITA° Classification

Colorimetric value displayL*, a*, b*, C*, h, Munsell value (Hue, Value, Chroma)*1
Graph displayHue-Value graph, Hb Index-Melanin Index graph, ITA° graph, 2D user-specified axis graph*2
Observer*32°, 10°
Illuminant*3C, D65
Data HandlingSaving / reading data in CM-SA2 original format

Saving data in text (CSV) format

[Melanin Index, Hb Index, Hb SO2 Index (%), L*, a*, b*, C*, h, Munsell value (Hue, Value, Chroma), ITA°, Spectral reflectance

(400-700 nm)*4]

Display languagesJapanese, English, Chinese (Simplified and Traditional), Korean
OtherDisplay of images at measurement*5

 

Compatible Spectrophotometers

Model*6CM-17d/CM-16d, CM-700d/CM-600d, CM-2600d/CM-2500d

 

Minimum Computing Requirements*7

OS: Windows® 10 Pro 64 bit Version 1903 or higher/Windows® 11 Pro

CPU: Intel® Core i5 2.7 GHz or higher processor (recommended)

Memory: 2 GB or more (4 GB or more recommended)

Storage: 10 GB or more

USB port: Required for connection to instrument

Connection to external network: Required for activation

*1: Munsell data care calculated for 2° observer and Standard Illuminant C.
*2: Colorimetric values for each axis can be selected from L*, a*, b*, C*, and h.
*3: Illuminant / Observer can be select from one of the four conditions. ( 2°/C, 2°/D65, 10°/C, 10°/D65 )
*4: The spectral reflectance data is obtained in SCI (Specular component included) mode and can only be displayed in CSV file format (output is 400 nm to 700 nm).
*5: The image is only displayed for data measured with the CM-17d connected and the Save Viewfinder image with measurement setting turned on.
*6: Instrument with older firmware may not be supported. To check compatible firmware versions for supported instruments, please visit: https://www.konicaminolta.com/instruments/download/software/color/cmsa2/index.html
 *7: The hardware of the computer system must meet or exceed the greater of the recommended system requirements for the compatible OS being used or the above specifications.
**Specifications subject to change without notice.

 

 